全部作者:郑红旗 徐催 陈九法
文献出处:建筑热能通风空调
论文摘要:
【摘要】 针对工程设计中闭式地表水换热器基础数据缺乏的问题,本文建立了闭式U型地表水换热器的三维传热模型,利用FLUENT软件,分别模拟了夏季与冬季工况下,换热器不同进口温度、不同湖水温度下换热器的传热特性。结果表明,换热器进出口平均温度与湖水温差、换热器进口温度与湖水温差是影响单位管长换热量的根本因素,并根据模拟结果分别拟合了两种温差与单位管长换热量的关系曲线。利用自主设计的实验台,在夏季与冬季分别进行了散热与取热实验,将由拟合公式计算的结果与实验结果进行了对比,误差在10%以内。本文给地表水换热器的工程设计提供了一条新思路。 【Abstract】 Three-dimensional model of closed-loop surface water heat exchanger was built,and heat transfer performance of different inlet water temperature of heat exchanger and lake water temperature were studied based on FLUENT software under summer and winter operation condition.Results indicate that temperature difference between average temperature of inlet and outlet and lake water temperature,and temperature difference between inlet and lake water temperature are the fundamental factor to inflect heat transfer quantity.Relationship curves between two temperature difference and heat transfer quantity per meter were fitted.Field tests on heat rejected to and extracted from lake were carried out based on experimental table developed independently.Results based on curve fitting and experimental results were compared,and relative error is in range of 10%.This paper provides a new idea of engineering design and application of closed-loop surface water heat exchanger. 【关键词】 闭式地表水换热器; 温差; 单位管长换热量 【Key words】 closed-loop surface water heat exchanger; temperature difference; heat transfer quantity per meter
关键词:暖通空调论文 闭式地表水换热器
☉尊重知识产权,引用文档中他人文字请注明文章出处!
☉下载压缩包文件时,如要求输入解压密码,统一为 www.51hvac.com 或 www.e-hvacr.com
☉推荐使用网际快车下载本站软件,使用 WinRAR v3.10 以上版本解压本站软件。
☉如果这个软件总是不能下载的请点击报告错误,谢谢合作!!
☉下载本站资源,如果服务器暂不能下载请过一段时间重试!
☉如果遇到什么问题,请到本站论坛去咨寻,我们将在那里提供更多 、更好的资源!
☉本站提供的一些商业软件是供学习研究之用,如用于商业用途,请购买正版。
☉当您打开下载地址链接后,无法下载文件时,请查看是否在地址栏中提示“为帮助保护您的安全,Internet Explorer 已经阻止从此站点下载文件到您的计算机。单击此处查看选项...”,请鼠标点击该提示选择“下载文件”即可。