全部作者:陈超 孙凤岭 冯磊
文献出处:《暖通空调》 年份:2005 期数:12
论文摘要:
【英文篇名】 Energy efficient operation of underground water-source 孙凤岭; 冯磊; 王陈栋; 【作者英文名】 By Chen Chao; Sun Fengling; Feng Lei and Wang ChendongBeijing University of Technology; Beijing; China; 【作者单位】 北京工业大学; 【文献出处】 暖通空调, Hv 能耗分析; 变频技术; 节能运行; 【英文关键词】 underground water-source energy consumption analysis; variable frequency technology; energy efficient operation; 【摘要】 根据笔者提出的共用空调动力设备和末端空调水源热泵机组耗电量的推算方法,对北京某公寓地下水源水环热泵空调系统两年多的实测数据进行了分析研究。结果表明,原有系统的二次循环水泵系统能耗大、部分负荷调节性差。对水泵系统进行了节能改造,在原有的定流量二次循环泵上增设变频器。改造后二次循环水泵的节电效率高达35%,节能效果十分显著。 【英文摘要】 Analyses more than two years field-test data of the underground water-source & water loop heat pump air conditioning system applied to an apartment in Beijing based on the computative method of calculating the electricity consumption of public-used air conditioning driven equipment and terminal heat pump units by the authors. The results show that the secondary circulating pump system of the original system consumes a lot of energy and its control performance is poor under partial load. Puts forward a schem... 【基金】 北京市重点实验室资助项目(编号:KF200406)
关键词:节能 运行 研究 系统 空调 地下