全部作者:赵雷昌
文献出处:《暖通空调》 年份:2010 期数:4
论文摘要:
摘要 针对数控厂房体量大、金属加工液污染源分散的特点,提出了分层空调+周围捕获的方案。分别对重污染机床未隔离和隔离时厂房内的气雾浓度进行了分析计算,其结论验证了污染物的周围捕获效果优于集中捕获。采用分层空调+周围捕获方案能有效地清除厂房内的污染物。 关键词 大型数控厂房 金属加工液 气雾浓度 集中捕获 周围捕获 分层空调 Ventilation and air conditioning system for large part numerical control machining buildings By Zhao Leichang Abstract In view of the characteristics of large space and dispersed pollutant sources of metal machining fluid, proposes a ventilation and air conditioning system scheme, i.e. stratified air conditioning plus peripheral collecting. Analyses and calculates the smog concentration in a machining building respectively on the conditions of isolated and non-isolated heavy pollution source machines, and the results prove that the effect of peripheral collecting is superior to that of centralized collecting. The effect of the scheme of stratified air conditioning plus peripheral collecting is satisfactory. Keywords large-scale numerical control machining building, metal machining fluid, smog concentration, centralized collecting, peripheral collecting, stratified air conditioning
关键词:大型数控厂房 属加工液 雾浓度