全部作者:任勤 周亚素 张恒钦 

文献出处:建筑热能通风空调

论文摘要:
【中文摘要】 根据热力学和传热学理论分析,建立了逆流闭式冷却塔热传递过程的微分方程组,并利用湿球温度与湿空气饱和温度在空气-水系统中数值上相等以及湿空气饱和线线性两种合理的假设推导得到了基于空气湿球温度的数学模型。对某逆流闭式冷却塔基于湿球温度的换热模型应用Matlab作四阶Runge-kutta数值求解,得到了冷却循环水、喷淋水、空气干湿球温度的变化规律,基于此模型可分析湿球温度对逆流闭式冷却塔冷却效率的影响,同时为今后此类冷却塔的开发提供理论支撑。 【英文摘要】 A differential equation group of heat and mass transfer process was obtained in term of analyzing of thermodynamics and heat transfer theoretically in counter-flow closed cooling tower.Meanwhile,the heat transfer model of wet bulb temperature was established based on two reasonable hypothesis that the numerical value of wet bulb temperature and saturated moist air temperature are equal in the air-water system,and linearity of moist saturated air line.The differential equation group was solved by IV order Runge-Kutta method.The temperature of circulated cooling water,spraying water,wet bulb and dry bulb along the height of cooler were analyzed.It provides a basis for analyzing the influence of wet bulb temperature on cooling effectiveness of counter-flow closed cooling tower,and supporting theoretically of future development of the same type of cooling tower. 【中文关键词】 逆流闭式冷却塔,湿球温度,冷却效率 【英文关键词】 counter-flow closed cooling tower; wet bulb temperature; cooling effectiveness

关键词:逆流闭式冷却塔 湿球温度 冷却效 

下载次数:8 文件大小:0B 文档类型:pdf
下载
相关下载

任勤 周亚素 张恒钦 发表的论文

与本论文相关的论文:逆流闭式冷却塔 湿球温度 冷却效 

下载说明

☉尊重知识产权,引用文档中他人文字请注明文章出处!
☉下载压缩包文件时,如要求输入解压密码,统一为 www.51hvac.comwww.e-hvacr.com
☉推荐使用网际快车下载本站软件,使用 WinRAR v3.10 以上版本解压本站软件。
☉如果这个软件总是不能下载的请点击报告错误,谢谢合作!!
☉下载本站资源,如果服务器暂不能下载请过一段时间重试!
☉如果遇到什么问题,请到本站论坛去咨寻,我们将在那里提供更多 、更好的资源!
☉本站提供的一些商业软件是供学习研究之用,如用于商业用途,请购买正版。
☉当您打开下载地址链接后,无法下载文件时,请查看是否在地址栏中提示“为帮助保护您的安全,Internet Explorer 已经阻止从此站点下载文件到您的计算机。单击此处查看选项...”,请鼠标点击该提示选择“下载文件”即可。

------分隔线----------------------------

论文下载排行榜

官方微信